Description
C442
Main Features
Heat resistance
Good flow
Good impact strength
Density: 1.04
Main Applications
Automotive interior (extruded profiles, interior trim),
Density: 1.04
Keys
Packaged product should be protected from the atmosferic agents and stored out of direct sunlight
NB: No Break
/M: Matt – Digit following letter
/M indicates increasing values of mattness
Properties |
Test Condition |
Test Methods |
Units |
|
General |
||||
Density |
ISO 1183 |
g/cm3 |
1.04 |
|
Water Absorption |
ASTM D 570 |
% |
0.3 |
|
Rheological |
||||
Melt Flow Rate (MFR) |
ISO 1133 |
g/10min |
6 |
|
Mechanical |
||||
Tensile Strength |
50 mm/min |
ASTM D 638 |
MPa |
43 |
Strain at break |
50 mm/min |
ASTM D 638 |
% |
45 |
Flexural Strength |
2 mm/min |
ASTM D 790 |
MPa |
65 |
Flexural Modulus |
2 mm/min |
ASTM D 790 |
MPa |
2300 |
Izod Impact Strength Notched |
+23°C – thickness 3.2 mm |
ISO 180/4A |
J/m |
200 |
0°C – thickness 3.2 mm |
ISO 180/4A |
J/m |
165 |
|
– 20°C – thickness 3.2 mm |
ISO 180/4A |
J/m |
125 |
|
– 40°C – thickness 3.2 mm |
ISO 180/4A |
J/m |
100 |
|
+23°C – thickness 4 mm |
ISO 180/1A |
kJ/m² |
17 |
|
– 40°C – thickness 4 mm |
ISO 180/1A |
kJ/m² |
9 |
|
Charpy Impact Strength, Notched |
+23°C |
DIN 53453 |
kJ/m² |
12 |
Unnotched |
+23°C |
DIN 53453 |
kJ/m² |
NB |
Unnotched |
– 40°C |
DIN 53453 |
kJ/m² |
NB |
Rockwell Hardness |
scale R |
ISO 2039/2 |
kJ/m² |
R110 |
Thermal |
||||
10 N – 120°C/h |
ISO 306/A120 |
ºC |
114 |
|
50 N – 120°C/h |
ISO 306/B120 |
ºC |
108 |
|
Deflection temp. under load (annealed) |
1.8 MPa – 120°C/h |
ASTM D 648 |
ºC |
108 |
Ceofficient of linear thermal expansion |
ASTM D 696 |
10 -5/ºC |
9 |
|
Thermal Conductivity |
ASTM C 177 |
W/(Km) |
0.17 |
|
Moulding Shrinkage |
ISO 294.4 |
% |
0.4-0.6 |
|
Flammability |
||||
Flame behavior |
thickness 1.5 mm |
UL 94 |
class |
HB |
Glow wire test |
thickness 3 mm |
IEC 60695-2-1 |
ºC |
650 |
Electrical |
||||
Surface resistivity |
dry |
IEC 60093 |
ohm |
10+14 |
Volume resistivity |
dry |
IEC 60093 |
ohm*cm |
10+15 |
Dielectric strength |
dry |
IEC 60243 |
kV/mm |
30 |
Dielectric constant (relative permittivity) |
1000 Hz – dry |
IEC 60250 |
3.1 |
|
Dissipation factor |
1000 Hz – dry |
IEC 60250 |
15*10-³ |
Reviews
There are no reviews yet.